Home » Volumes » Volume 33 July/August 2000 » Diagnosis of rubella infection by detecting specific immunoglobulin M antibodies in saliva samples: a clinic-based study in Niterói, RJ, Brazil

Diagnosis of rubella infection by detecting specific immunoglobulin M antibodies in saliva samples: a clinic-based study in Niterói, RJ, Brazil

Solange Artimos de Oliveira1, Marilda Mendonça Siqueira2, David W.G. Brown4, Pamella Litton4, Luís Antonio B. Camacho3, Sílvia Thees Castro1 and Bernard J. Cohen4

1. Disciplina de Doenças Infecciosas e Parasitárias da Faculdade de Medicina da Universidade Federal Fluminense, Niterói, RJ, 2. Departamento de Virologia do Instituto Oswaldo Cruz; 3. Escola Nacional de Saúde Pública/FIOCRUZ, Rio de Janeiro, RJ; 4. Enteric and Respiratory Virus Laboratory, Central Public Health Laboratory, London, UK.

DOI: 10.1590/S0037-86822000000400001


ABSTRACT: This study was designed to investigate whether saliva could be a feasible alternative to serum for the diagnosis of recent rubella infection in a clinic setting. Forty-five paired blood and saliva samples collected 1 to 29 days after onset of illness were tested for specific immunoglobulin (Ig) M by antibody-capture radioimmunoassay (MACRIA). Rubella IgM was detected in all serum samples and in 38 (84.4%) saliva specimens. Forty-six serum and saliva samples from other patients with rash diseases were tested by MACRIA for control purposes and two saliva specimens were reactive. The saliva test had specificity of 96%. These results indicate that salivary IgM detection may be a convenient non-invasive alternative to serum for investigation of recent rubella cases, especially for disease surveillance and control programmes.
Key-words:
 Rubella. Saliva. Diagnosis. IgM. Antibody-capture radioimmunoassay.

RESUMO: Este estudo foi realizado para avaliar a validade da utilização da saliva no diagnóstico laboratorial da rubéola. Quarenta e cinco amostras pareadas de sangue e de saliva, coletadas de 1 a 29 dias após o início da doença, foram testadas para detecção de imunoglobulina (Ig) M específica por radioimunoensaio com captura (MACRIA). Anticorpos IgM específicos contra rubéola foram detectados em todas as amostras sangüíneas e em 38 (84,4%) das amostras de saliva. A especificidade do teste na saliva foi de 96%. Estes resultados indicam que a utilização da saliva pode ser uma alternativa válida para obtenção de espécimens clínicos na investigação de casos recentes de rubéola, especialmente nas atividades de vigilância epidemiológica e controle da virose.
Palavras-chaves
Rubéola. Saliva. Diagnóstico. IgM. Radioimunoensaio.

 

 

The infection caused by rubella virus is usually mild or asymptomatic in adults and children. However, rubella infection in pregnant women, especially during the first trimester, can result in miscarriage, stillbirth, and congenital defects19. Live attenuated rubella vaccines were licensed in USA in 1969 and have been used widely in many industrialised countries since that time7 20. Since 1987, some states in Brazil have added rubella vaccines to their immunisation programmes, using a variety of different schedules. A national programme to control the disease and congenital rubella syndrome (CRS) was introduced in 1997 by implementation of rubella vaccination and surveillance of CRS and acquired rubella cases6.

The features of rubella infection overlap considerably with other viral infections that present erythematous rashes, and it is sometimes difficult to make a diagnosis on clinical grounds alone. Laboratory diagnosis of recent or past rubella is particularly important for pregnant women and for the design and monitoring of vaccination programmes3 21.

However, the requirement to take blood samples is not always practical, and limits its widespread use, particularly for those populations outside the clinical environment and for children11 13 21. The use of saliva as a non-invasive alternative to serum for detecting virus specific antibodies was first described by Parry et al15. Subsequently, specific IgM in saliva was detected successfully in patients with recent hepatitis A or B16, measles, mumps, and rubella17, human parvovirus B194, and dengue fever14.

The objective of this study was to investigate whether saliva could be a feasible alternative to serum for the diagnosis of recent rubella infection under conditions in routine health care centres in Brazil.

MATERIAL AND METHODS

From January 1994 to January 1999 a study of the etiology of exanthematic diseases was conducted at the Department of Infectious Diseases of the Hospital Universitário Antonio Pedro, Niterói, RJ, and two other large Health Care Units from that Municipality. All patients seen at the selected study sites with an acute maculopapular rash were asked to participate and to consent to the collection of the specimens. A total of 473 cases were seen and 19.6% (94 cases) of them was confirmed by rubella specific IgM testing using a commercial ELISA (Rubenostika IgM, Organon). Paired blood and saliva samples collected simultaneously were available from 45 (47.9%) of the 94 rubella IgM positive cases. To allow specificity assessment, paired blood and saliva samples from 49 patients with other recent rash diseases (n measles, n parvovirus B19, n dengue) were tested.

A commercial device (OraSure, Epitope, Bearverton, OR, USA) was used to collect saliva specimen. According to the manufacturer’s instructions, a small pad of absorbent material was placed into the patient’s mouth between the lower cheek and gum and stroked back and forth several times until moistened. Then the pad was held in place for 2 min with the mouth closed. After that the pad was removed and inserted in the bottom of a vial containing preservative. The samples were kept refrigerated before being transported to the laboratory. Saliva was extracted from the absorbent pads by centrifugation (2500rpm for 15min) and stored at -20oC before testing.

Rubella IgM antibody assay. An antibody-capture radioimmunoassay (MACRIA) was used to detect rubella specific IgM in saliva and serum samples as previously described17. Briefly, polystyrene beads coated with rabbit antibody to human IgM (DAKO, Denmark) were incubated with either undiluted saliva samples or serum samples at a final dilution of 1 in 100. After washing with phosphate buffered saline with 0.05% Tween-20 (PBST) using the Abbott Qwikwash System (Abbott Diagnostics, Chicago, Il., USA), rubella haemagglutinin antigen [Judith strain, HA titre 1:256, Batch nº 2168/1 (Laboratory of Microbiological Reagents, CPHL, Colindale, UK)] was incubated with the beads overnight at 4oC. The beads were then washed with PBST, and monoclonal antibody to rubella haemagglutinin (Laboratory of Microbiological Reagents) was added and incubated for 2h at 37oC. Finally the beads were washed in PBST and incubated for 2h at 37oC with 125I-labelled sheep anti-mouse IgG (Code IM 131, Amersham International, UK). Beads were washed and the bound radioactivity was measured in a gamma counter. Specimens were considered positive for IgM if they gave a test: negative (T:N) ratio ³ 3.0. T:N values < 3.0 were regarded as negative for this study17.

Total IgG assay. Saliva total IgG content was determined to verify the adequacy of the specimen, by using an enzyme immunoassay (EIA) as described before2.

Data analysis. The performance of rubella MACRIA on saliva samples was assessed by calculating (a) the proportion of individuals with rubella IgM in saliva among those with rubella IgM in serum (sensitivity) and (b) the proportion of individuals without detectable rubella IgM in saliva among those rubella IgM negative in serum (specificity).

 

RESULTS

Forty-five (47.9%) of the 94 rubella cases seen in the participating institutions were enrolled in this study. Paired blood and saliva samples were taken from the 45 cases from 1 to 29 days after onset of illness. No patient or patient’s parents refused permission for sampling to be performed. The ages of the patients ranged from 1 to 46 years, with 56.6% (25 cases) below 15 years old. The most common symptoms found to be associated with rubella infection were rash (100%), pyrexia (68.9%), post-auricular and/or occipital lymphadenopathy (60%), cough and/or coryza (57.8%) and arthropathy (37.8%). Of the 45 rubella cases, only 1 had a history of MMR (measles, mumps, and rubella) vaccine in the past.

Overall, rubella-specific IgM was detected in 38/45 (84.4%) saliva samples of patients with rubella-specific IgM in serum. Table 1 shows the detection of virus-specific IgM in saliva according to the day of onset of illness.

For control purposes, 49 paired blood and saliva samples collected from patients with diseases with rash not related to rubella infection (serum rubella IgM negative by the commercial ELISA mentioned above) were also tested. The specimens were collected within 30 days after the onset of disease. The age of the patients ranged from 15 days to 36 years. Forty six sera were negative by rubella MACRIA but 3 sera gave repeated reactivity (T:N 3.7, 3.2, 7.3), while corresponding saliva specimens were unreactive in 2 cases and weakly reactive (T:N 3.3) in 1 case. As we were unable to evaluate the discordant results either by using a third rubella IgM test or to demonstrate rising titres of rubella antibody in paired serum samples or to demonstrate low avidity rubella IgG, the three cases were regarded as inconclusive and excluded from the analysis. Of the remaining 46 paired blood and saliva samples taken for control purposes, 2 saliva specimens showed some rubella-specific IgM reactivity (T:N 4.8, 5.0). The predictive value of a positive test for saliva rubella IgM in this study was 95% and the predictive value of a negative test was 86.3%.

The concentration of total IgG saliva specimens was assessed in 6 of the 7 false negative salivary rubella specific IgM samples. One out of six samples contained low levels of total IgG (4.0mg/l). For the other 5 samples, the total IgG concentration ranged from 9.1 to > 58mg/l.

 

DISCUSSION

Some studies about detection of rubella class-specific antibodies from saliva specimens are described in the literature1 5 13 17 18 21. Perry et al17, using antibody-capture radioimmunoassay, showed that virus specific IgM was detected in 100% of rubella saliva samples collected between 1 and 5 weeks after onset of disease. Ramsay et al18 in a community-based study of notified cases of rubella in England and Wales found that the sensitivity of saliva rubella IgM testing was 81%. However, the sensitivity rose to 90% when results from specimens collected outside the recommended period (1-6 weeks after onset) and specimens taking more than 1 week to reach the laboratory were excluded. Our results are similar to those reported by Ramsay et al18. Rubella specific IgM was detected in 84.4% of saliva specimens, demonstrating high level of concordance between blood and saliva IgM results. The saliva test had a specificity of 96%.

Inadequate saliva collection could have contributed to a missed salivary diagnosis. However, in 5 of the 7 false negative cases the total IgG concentration indicated adequate samples. Notwithstanding that Perry et al17 have stated that salivary concentration of total IgG is an adequate criterion for assessing the quality of the specimens, other studies have suggested that inadequate saliva samples might not explain false negative IgM results1 14.

As stated above, timing of salivary specimen collection is another important factor in determining whether viral specific IgM will be detected3 18. However, this factor does not seem to have contributed to miss salivary diagnosis in the present study: only 1 out of the 7 false negative IgM saliva samples was obtained outside the recommended period17.

The results presented in this study indicate that saliva may be a viable alternative to serum for community rubella surveys and surveillance in Brazil. Besides the introduction of a national programme to control the disease and CRS in 1997, accurate surveillance of acquired rubella and CRS has been a critical component of the Brazilian Vaccine Programme6. The mildness of the majority of rubella cases makes parents and medical practitioners reluctant to take blood for diagnosis. Moreover, in developing countries rubella outbreaks can occur with no clinical recognition, even in a community in which health is being monitored9. The use of non-invasive specimens for diagnosis offers several advantages over blood such as: acceptability to patients, applicability to children10, reuse of disposable equipment is avoided and the occupational risk from needlestick injures is eliminated8.

The present work and other recent studies1 12 18 21 indicate that saliva is a viable alternative to serum for monitoring the impact of vaccination programmes in the future. These results highlight the need of development of simple assays such as enzyme-linked immunosorbent assay for salivary rubella IgM for use in public health laboratories worldwide.

 

ACKNOWLEDGEMENTS

We thank the general practitioners from the Department of Infectious Diseases/University Federal Fluminense and Centro de Saúde Santa Rosa for their help in collecting the saliva samples and Mr. Rashpal Hunjan from Enteric and Respiratory Virus Laboratory/CPHL, London, UK, for technical work. We also thank Fundação Oswaldo Cruz, The British Council and Conselho Nacional de Pesquisa e Desenvolvimento for providing financial support for the research.

 

REFERENCES

1. Azevedo Neto RS, Richards A, Nokes DJ, Silveira ASB, Cohen BJ, Passos SD, Souza VAUF, Brown DWG, Pannuti CS, Massad E. Salivary antibody detection inepidemiological surveys: a pilot study after a mass vaccination campaign against rubella in São Paulo, Brazil. Transactions of the Royal Society of Tropical Medicine and Hygiene 89:115-118, 1995.         [ Links ]

2. Connell JA, Parry JV, Mortimer PP, Duncan J. Accurate assays for anti-HIV in urine. Lancet 335:1266-1269, 1990.         [ Links ]

3. Cradick-Watson JE. Laboratory diagnosis of rubella: past, present and future. Epidemiology and Infection 107:1-15, 1991.         [ Links ]

4. Cubel RCN, Oliveira SA, Brown DWG, Cohen BJ, Nascimento JP. Diagnosis of B19 infection by detection of specific immunoglobulin M antibody in saliva. Journal of Clinical Microbiology 34:205-207, 1996.         [ Links ]

5. Eckstein MB, Brown DWG, Foster A, Richards AF, Gilbert CE, Vijayalakshmi P. Congenital rubella in South India ¾diagnosis using saliva from infants with cataract. British Medical Journal 312:161, 1996.         [ Links ]

6. Fundação Nacional de Saúde. Centro Nacional de Epidemiologia. Plano de Controle da Rubéola e da Síndrome da Rubéola Congênita. Ministério da Saúde. Brasília, 1998.         [ Links ]

7. Hinman AR, Hersh BS, De Quadros CA. Rational use of rubella vaccine for prevention of congenital rubella syndrome in the Americas. Twelfth Meeting of the Technical Advisory Group on Vaccines Preventable Diseases. Guatemala City, Guatemala. Pan American Health Organization, 1997.         [ Links ]

8. Holm-Hansen C, Constantine NT, Haukenes G. Detection of antibodies to HIV in homologous sets of plasma, urine and oral mucosal transudate samples using rapid assays in Tanzania. Clinical and Diagnostic Virology 1:207-214, 1993.         [ Links ]

9. Miller CL. Rubella in the developing world. Epidemiology and Infection 107:63-68, 1991.         [ Links ]

10. Mortimer PP. Antibody tests: progress and pitfalls. Clinical and Diagnostic Virology 5:131-136, 1996.         [ Links ]

11. Mortimer PP, Parry JV. Non-invasive virological diagnosis: are saliva and urine specimens adequate substitutes for blood? Reviews in Medical Virology 1:73-78, 1991.         [ Links ]

12. Nokes DJ, Enquselassie F, Vyse A, Nigatu W, Cutts FT, Brown DWG. An evaluation of oral-fluid collection devices for the determination of rubella antibody status in a rural Ethiopian community. Transactions of the Royal Society of Tropical Medicine and Hygiene 92:679-685, 1998.         [ Links ]

13. Nokes DJ, Nigatu W, Abebe A, Messele T, Desene A, Enquselassie F, Vyse AJ, Brown DWG, Cutts F. A comparison of oral fluid and serum for the detection of rubella-specific antibodies in a community study in Addis Ababa, Ethiopia. Tropical Medical Internal Health 3:258-267, 1997.         [ Links ]

14. Oliveira SA, Rodrigues CVN, Camacho LAB, Miagostovich MP, Araújo ESM, Nogueira RMR. Diagnosis of dengue infection by detecting specific immunoglobulin M antibodies in saliva samples. Journal of Virological Methods 77:81-86, 1999.         [ Links ]

15. Parry JV, Perry KR, Mortimer PP. Sensitive assays for viral antibodies in saliva: an alternative to tests on serum. Lancet II:72-75, 1987.         [ Links ]

16. Parry JV, Perry KR, Panday S, Mortimer PP. Diagnosis of hepatitis A and B by testing saliva. Journal of Medical Virology 28:255-260, 1989.         [ Links ]

17. Perry KR, Brown DWG, Parry JV, Panday S, Pipkin C, Richards A. Detection of measles, mumps, and rubella antibodies in saliva using antibody capture radio-immunoassay. Journal of Medical Virology 40:235-240, 1993.         [ Links ]

18. Ramsay ME, Brugha R, Brown DWG, Cohen BJ, Miller E. Salivary diagnosis of rubella: a study of notified cases in the United Kingdom, 1991-1994. Epidemiology and Infection 120:313-319, 1998.         [ Links ]

19. Reef SE. Rubella and congenital rubella syndrome. Bulletin of the World Health Organization 76:156-157, 1998.         [ Links ]

20. Robertson SE, Cutts FT, Samuel R, Diaz-Ortega JL. Control of rubella and congenital rubella syndrome (CRS) in developing countries, part 2: vaccination against rubella. Bulletin of the World Health Organization 75:69-80, 1997.         [ Links ]

21. Vyse AJ, Brown DWG, Cohen BJ, Samuel R, Nokes DJ. Detection of rubella virus-specific immunoglobulin G in saliva by an amplification-based enzyme-linked immunosorbent assay using monoclonal antibody to fluorescein isothiocyanate. Journal of Clinical Microbiology 37:391-395, 1999.         [ Links ]